| Physical properties | Standard | Value | Measure Units | |
|---|---|---|---|---|
| Density | ISO 1183 | 1.5 | g/cm³ | |
| Linear shrinkage at moulding | ||||
| Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.05 ÷ 0.15 | % | |
| Transversal (2.0mm/60MPa) | ISO 294-4 | 0.35 ÷ 0.55 | % | |
| Dimensional stability | --- | 65 | ||
| Moisture absorption | ||||
| Saturation, in air | ISO 62-4 | 0.02 | % | |
| Mechanical properties | Standard | Value | Measure Units | |
| CHARPY impact strength | ||||
| Unnotched, at +73°F | ISO 179-1eU | 4.7 | ft.lb/in² | |
| Notched, at +73°F | ISO 179-1eA | 1.6 | ft.lb/in² | |
| Tensile elongation | ||||
| At break (5 mm/min), 73°F | ISO 527 | 0.5 | % | |
| At break (5 mm/min), 140°F | ISO 527 | 0.5 | % | |
| At break (5 mm/min), 195°F | ISO 527 | 1 | % | |
| At break (5 mm/min), 250°F | ISO 527 | 1 | % | |
| At break (5 mm/min), 300°F | ISO 527 | 1 | % | |
| Tensile strength | ||||
| At break (5 mm/min), 73°F | ISO 527 | 25500 | psi | |
| At break (5 mm/min), 140°F | ISO 527 | 18000 | psi | |
| At break (5 mm/min), 195°F | ISO 527 | 16500 | psi | |
| At break (5 mm/min), 250°F | ISO 527 | 10500 | psi | |
| At break (5 mm/min), 300°F | ISO 527 | 9000 | psi | |
| Elastic modulus | ||||
| Tensile (1 mm/min), 73°F | ISO 527 | 5100 | kpsi | |
| Tensile (1 mm/min), 140°F | ISO 527 | 4200 | kpsi | |
| Tensile (1 mm/min), 195°F | ISO 527 | 2400 | kpsi | |
| Tensile (1 mm/min), 250°F | ISO 527 | 1800 | kpsi | |
| Tensile (1 mm/min), 300°F | ISO 527 | 1395 | kpsi | |
| Thermal properties | Standard | Value | Measure Units | |
| Coefficient of linear thermal expansion (CLTE) | ||||
| +30°C to +100°C (longitudinal) | ISO 11359 | 2 | × 10ˉ⁶ Kˉ¹ | |
| +30°C a +100°C (transversal) | ISO 11359 | 20 | × 10ˉ⁶ Kˉ¹ | |
| VICAT - Softening point | ||||
| 50N (heating rate 120°C/h) | ISO 306 | 491 | °F | |
| HDT - Heat Deflection Temperature | ||||
| 0.45 MPa | ISO 75 | 536 | °F | |
| 1.81 MPa | ISO 75 | 518 | °F | |
| Thermal conductivity | ||||
| in plane | ASTM E 1461-92 | 5.2 | W/mK | |
| through plane | ASTM E 1461-92 | 2.4 | W/mK | |
| Flammability | Standard | Value | Measure Units | |
| Flammability rating | ||||
| 3 mm thickness | UL 94 | V-0 | ||
| 1.5 mm thickness | UL 94 | V-0 | ||
| 0.75 mm thickness | UL 94 | V-0 | ||
| GWFI - Glow Wire Flammability Index | ||||
| 2 mm thickness | IEC 60695-2-12 | 960 | °C | |
| 1 mm thickness | IEC 60695-2-12 | 960 | °C | |
| GWIT - Glow Wire Ignition Test | ||||
| 2 mm thickness | IEC 60695-2-13 | 775 | °C | |
| 1 mm thickness | IEC 60695-2-13 | 775 | °C | |
| Electrical properties | Standard | Value | Measure Units | |
| Electrical resistivity | ||||
| Surface, dry | IEC 62631 | 5E1 | ohm | |
| Volume | IEC 62631 | 1E2 | ohm.cm | |
| Dielectric strength (short period) | ||||
| 2 mm thickness, 23°C, dry | ASTM D 149 | 51 | V/mil | |
| Melt Temperature | Standard | Value | Measure Units | |
| Suggested melt temperature | --- | 555 ÷ 625 | °F | |
| Mould Temperature | Standard | Value | Measure Units | |
| Suggested mould temperature | --- | 275 ÷ 300 | °F |