Physical properties | Standard | Value | Measure Units |
---|---|---|---|
Density | ISO 1183 | 1.38 | g/cm³ |
Linear shrinkage at moulding | |||
Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.45 ÷ 0.75 | % |
Transversal (2.0mm/60MPa) | ISO 294-4 | 0.90 ÷ 1.20 | % |
Dimensional stability | --- | 53 | |
Moisture absorption | |||
Saturation, in air | ISO 62-4 | 0.3 | % |
Mechanical properties | Standard | Value | Measure Units |
CHARPY impact strength | |||
Unnotched, at +73°F | ISO 179-1eU | 45 | ft.lb/in² |
Notched, at +73°F | ISO 179-1eA | 2.6 | ft.lb/in² |
Tensile elongation | |||
At yield (5 mm/min), 73°F | ISO 527 | 2.8 | % |
At break (5 mm/min), 73°F | ISO 527 | 4.5 | % |
Tensile strength | |||
At yield (5 mm/min), 73°F | ISO 527 | 4350 | psi |
At break (5 mm/min), 73°F | ISO 527 | 7500 | psi |
Elastic modulus | |||
Tensile (1 mm/min), 73°F | ISO 527 | 165 | kpsi |
Thermal properties | Standard | Value | Measure Units |
Coefficient of linear thermal expansion (CLTE) | |||
+30°C to +100°C (longitudinal) | ISO 11359 | 50 | × 10ˉ⁶ Kˉ¹ |
+30°C a +100°C (transversal) | ISO 11359 | 80 | × 10ˉ⁶ Kˉ¹ |
VICAT - Softening point | |||
50N (heating rate 120°C/h) | ISO 306 | 230 | °F |
HDT - Heat Deflection Temperature | |||
0.45 MPa | ISO 75 | 122 | °F |
1.81 MPa | ISO 75 | 115 | °F |
Electrical properties | Standard | Value | Measure Units |
CTI - Comparative Tracking Index - solution A (without surfactant) | IEC 60112 | 600 | V |
Electrical resistivity | |||
Surface, dry | ASTM D 257 / D 4496 | 1E12 | ohm |
Dielectric strength (short period) | |||
2 mm thickness, 23°C, dry | ASTM D 149 | 559 | V/mil |
Melt Temperature | Standard | Value | Measure Units |
Suggested melt temperature | --- | 400 ÷ 430 | °F |
Mould Temperature | Standard | Value | Measure Units |
Suggested mould temperature | --- | 70 ÷ 120 | °F |