Customer support: +39-0332 409111
Email: marketing@it.lati.com

LASTILAC AR-V0E

Family: LASTILAC
Base resin:Acrylonitrile-Butadiene-Styrene copolymer (ABS)
General information
Compound based on Acrylonitrile-Butadiene-Styrene copolymer (ABS). Flame retardant, UL94 V-0 class, with brominated flame retardants, free of PBB/PBDE.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Flame retardant, with brominated flame retardants
Project challenges
  • - Wear and friction
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.21 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.40 ÷ 0.60 %
Transversal (2.0mm/60MPa) ISO 294-4 0.45 ÷ 0.65 %
Dimensional stability --- 79
Moisture absorption
Saturation, in air ISO 62-4 0.39 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +73°F ISO 179-1eU 19 ft.lb/in²
Notched, at +73°F ISO 179-1eA 3 ft.lb/in²
Tensile elongation
At yield (5 mm/min), 73°F ISO 527 2.2 %
At yield (5 mm/min), 140°F ISO 527 2.4 %
At yield (5 mm/min), 195°F ISO 527 2.5 %
At break (5 mm/min), 73°F ISO 527 8 %
At break (5 mm/min), 140°F ISO 527 50 %
At break (5 mm/min), 195°F ISO 527 95 %
Tensile strength
At yield (5 mm/min), 73°F ISO 527 6000 psi
At yield (5 mm/min), 140°F ISO 527 4350 psi
At yield (5 mm/min), 195°F ISO 527 2900 psi
At break (5 mm/min), 73°F ISO 527 5250 psi
At break (5 mm/min), 140°F ISO 527 2900 psi
At break (5 mm/min), 195°F ISO 527 725 psi
Elastic modulus
Tensile (1 mm/min), 73°F ISO 527 345 kpsi
Tensile (1 mm/min), 140°F ISO 527 270 kpsi
Tensile (1 mm/min), 195°F ISO 527 210 kpsi
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 75 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 75 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 203 °F
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 194 °F
1.81 MPa ISO 75 176 °F
Flammability Standard Value Measure Units
Oxygen Index ASTM D 2863 28 %
Flammability rating
3 mm thickness UL 94 V-0
1.5 mm thickness UL 94 V-0
0.75 mm thickness UL 94 V-2
GWFI - Glow Wire Flammability Index
2 mm thickness IEC 60695-2-12 960 °C
1 mm thickness IEC 60695-2-12 960 °C
GWIT - Glow Wire Ignition Test
2 mm thickness IEC 60695-2-13 725 °C
1 mm thickness IEC 60695-2-13 850 °C
Electrical properties Standard Value Measure Units
CTI - Comparative Tracking Index - solution A (without surfactant) IEC 60112 350 V
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Dielectric strength (short period)
2 mm thickness, 23°C, dry ASTM D 149 457 V/mil
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 375 ÷ 430 °F
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 105 ÷ 140 °F
Drying conditions (hot air dessiccator)
Predrying needed. At least 3 hours at 160 ÷ 175°F
Injection speed
Injection speed: low to medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: not suggested