Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATAMID 66 E21

Family: LATAMID 66
Base resin:Polyamide 66 (PA 66)
General information
Compound based on Polyamide 66 (PA 66). Toughened. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Toughened
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.07 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 2.00 ÷ 2.30 %
Transversal (2.0mm/60MPa) ISO 294-4 1.80 ÷ 2.00 %
Dimensional stability --- 75
Moisture absorption
Saturation, in air ISO 62-4 2.1 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Notched, at +73°F ISO 179-1eA 40 ft.lb/in²
Notched, at -4°F ISO 179-1eA 9 ft.lb/in²
Tensile elongation
At yield (5 mm/min), 73°F ISO 527 5 %
At yield (5 mm/min), 300°F ISO 527 >10 %
Tensile strength
At yield (5 mm/min), 73°F ISO 527 6750 psi
At yield (5 mm/min), 140°F ISO 527 3625 psi
At yield (5 mm/min), 195°F ISO 527 2175 psi
At yield (5 mm/min), 250°F ISO 527 1450 psi
At yield (5 mm/min), 300°F ISO 527 725 psi
Elastic modulus
Tensile (1 mm/min), 73°F ISO 527 240 kpsi
Tensile (1 mm/min), 140°F ISO 527 102 kpsi
Tensile (1 mm/min), 195°F ISO 527 80 kpsi
Tensile (1 mm/min), 250°F ISO 527 51 kpsi
Tensile (1 mm/min), 300°F ISO 527 44 kpsi
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 100 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 140 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 374 °F
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 275 °F
1.81 MPa ISO 75 140 °F
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Dielectric strength (short period)
2 mm thickness, 23°C, dry ASTM D 149 508 V/mil
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 520 ÷ 555 °F
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 140 ÷ 195 °F
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 160 ÷ 195°F
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible