Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATILUB 73/13-20ST

Family: LATILUB
Base resin:Polyoximethylene (POM)
General information
Self-lubricating product based on Polyoximethylene (POM). Silicone / PTFE.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Self lubricant
Additives
  • - PTFE
  • - Silicone
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.48 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 2.15 ÷ 2.50 %
Transversal (2.0mm/60MPa) ISO 294-4 2.20 ÷ 2.45 %
Dimensional stability --- 70
Moisture absorption
Saturation, in air ISO 62-4 0.18 %
Melt Flow Index (MFI) ASTM D 1238 10.00@375°F/4.76lbs g/10'
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +73°F ISO 179-1eU 21 ft.lb/in²
Notched, at +73°F ISO 179-1eA 1.6 ft.lb/in²
Tensile elongation
At break (5 mm/min), 73°F ISO 527 20 %
Tensile strength
At yield (5 mm/min), 73°F ISO 527 6750 psi
At break (5 mm/min), 73°F ISO 527 6750 psi
Elastic modulus
Tensile (1 mm/min), 73°F ISO 527 285 kpsi
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 120 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 120 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 302 °F
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 293 °F
1.81 MPa ISO 75 176 °F
Thermal conductivity
in plane ASTM E 1461-92 1.7 W/mK
through plane ASTM E 1461-92 1.7 W/mK
Flammability Standard Value Measure Units
Flammability rating
3 mm thickness UL 94 HB
1.5 mm thickness UL 94 HB
Electrical properties Standard Value Measure Units
CTI - Comparative Tracking Index - solution A (without surfactant) IEC 60112 600 V
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Dielectric strength (short period)
2 mm thickness, 23°C, dry ASTM D 149 457 V/mil
Tribological properties Standard Value Measure Units
Wear Factor LATI 70 10ˉ⁸(mm³m)/N
Friction Coefficient
Static LATI 0.19
Dynamic LATI 0.24
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 375 ÷ 410 °F
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 175 ÷ 250 °F
Drying conditions (hot air dessiccator)
Predrying needed. At least 3 hours at 175 ÷ 250°F
Injection speed
Injection speed: medium to high. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible