| Physical properties | Standard | Value | Measure Units |
|---|---|---|---|
| Density | ISO 1183 | 1.5 | g/cm³ |
| Linear shrinkage at moulding | |||
| Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.35 ÷ 0.50 | % |
| Transversal (2.0mm/60MPa) | ISO 294-4 | 0.70 ÷ 0.85 | % |
| Dimensional stability | --- | 72 | |
| Moisture absorption | |||
| Saturation, in air | ISO 62-4 | 0.6 | % |
| At saturation, in water | ISO 62-4 | 1.6 | % |
| Melt Flow Index (MFI) | ASTM D 1238 | 18.00@380°C/2.16kg | g/10' |
| Mechanical properties | Standard | Value | Measure Units |
| CHARPY impact strength | |||
| Unnotched, at +23°C | ISO 179-1eU | 60 | kJ/m² |
| Notched, at +23°C | ISO 179-1eA | 8 | kJ/m² |
| Tensile elongation | |||
| At break (5 mm/min), 23°C | ISO 527 | 3.1 | % |
| At break (5 mm/min), 60°C | ISO 527 | 3.1 | % |
| At break (5 mm/min), 90°C | ISO 527 | 3.2 | % |
| At break (5 mm/min), 120°C | ISO 527 | 3.2 | % |
| At break (5 mm/min), 150°C | ISO 527 | 3.4 | % |
| Tensile strength | |||
| At break (5 mm/min), 23°C | ISO 527 | 130 | MPa |
| At break (5 mm/min), 60°C | ISO 527 | 115 | MPa |
| At break (5 mm/min), 90°C | ISO 527 | 105 | MPa |
| At break (5 mm/min), 120°C | ISO 527 | 95 | MPa |
| At break (5 mm/min), 150°C | ISO 527 | 80 | MPa |
| Elastic modulus | |||
| Tensile (1 mm/min), 23°C | ISO 527 | 6500 | MPa |
| Tensile (1 mm/min), 60°C | ISO 527 | 6300 | MPa |
| Tensile (1 mm/min), 90°C | ISO 527 | 6200 | MPa |
| Tensile (1 mm/min), 120°C | ISO 527 | 5900 | MPa |
| Tensile (1 mm/min), 150°C | ISO 527 | 5400 | MPa |
| Thermal properties | Standard | Value | Measure Units |
| Coefficient of linear thermal expansion (CLTE) | |||
| +30°C to +100°C (longitudinal) | ISO 11359 | 20 | × 10ˉ⁶ Kˉ¹ |
| +30°C a +100°C (transversal) | ISO 11359 | 50 | × 10ˉ⁶ Kˉ¹ |
| VICAT - Softening point | |||
| 50N (heating rate 120°C/h) | ISO 306 | 210 | °C |
| HDT - Heat Deflection Temperature | |||
| 0.45 MPa | ISO 75 | 215 | °C |
| 1.81 MPa | ISO 75 | 210 | °C |
| Thermal conductivity | |||
| in plane | ASTM E 1461-92 | 0.2 | W/mK |
| through plane | ASTM E 1461-92 | 0.2 | W/mK |
| Flammability | Standard | Value | Measure Units |
| Oxygen Index | ASTM D 2863 | 41 | % |
| Flammability rating | |||
| 3 mm thickness | UL 94 | V-0 | |
| 1.5 mm thickness | UL 94 | V-0 | |
| Electrical properties | Standard | Value | Measure Units |
| CTI - Comparative Tracking Index - solution A (without surfactant) | IEC 60112 | 125 | V |
| Electrical resistivity | |||
| Surface, dry | ASTM D 257 / D 4496 | 1E12 | ohm |
| Dielectric strength (short period) | |||
| 2 mm thickness, 23°C, dry | ASTM D 149 | 27 | kV/mm |
| Melt Temperature | Standard | Value | Measure Units |
| Suggested melt temperature | --- | 350 ÷ 380 | °C |
| Mould Temperature | Standard | Value | Measure Units |
| Suggested mould temperature | --- | 140 ÷ 180 | °C |