| Physical properties | Standard | Value | Measure Units | |
|---|---|---|---|---|
| Density | ISO 1183 | 1.4 | g/cm³ | |
| Linear shrinkage at moulding | ||||
| Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.10 ÷ 0.20 | % | |
| Transversal (2.0mm/60MPa) | ISO 294-4 | 0.50 ÷ 0.75 | % | |
| Dimensional stability | --- | 50 | ||
| Moisture absorption | ||||
| Saturation, in air | ISO 62-4 | 0.07 | % | |
| Mechanical properties | Standard | Value | Measure Units | |
| CHARPY impact strength | ||||
| Unnotched, at +23°C | ISO 179-1eU | 50 | kJ/m² | |
| Notched, at +23°C | ISO 179-1eA | 9 | kJ/m² | |
| Tensile elongation | ||||
| At break (5 mm/min), 23°C | ISO 527 | 1.8 | % | |
| At break (5 mm/min), 60°C | ISO 527 | 1.9 | % | |
| At break (5 mm/min), 90°C | ISO 527 | 2.1 | % | |
| At break (5 mm/min), 120°C | ISO 527 | 2.3 | % | |
| At break (5 mm/min), 150°C | ISO 527 | 2.5 | % | |
| Tensile strength | ||||
| At break (5 mm/min), 23°C | ISO 527 | 230 | MPa | |
| At break (5 mm/min), 60°C | ISO 527 | 220 | MPa | |
| At break (5 mm/min), 90°C | ISO 527 | 210 | MPa | |
| At break (5 mm/min), 120°C | ISO 527 | 200 | MPa | |
| At break (5 mm/min), 150°C | ISO 527 | 180 | MPa | |
| Elastic modulus | ||||
| Tensile (1 mm/min), 23°C | ISO 527 | 23000 | MPa | |
| Tensile (1 mm/min), 60°C | ISO 527 | 21000 | MPa | |
| Tensile (1 mm/min), 90°C | ISO 527 | 20000 | MPa | |
| Tensile (1 mm/min), 120°C | ISO 527 | 19000 | MPa | |
| Tensile (1 mm/min), 150°C | ISO 527 | 16000 | MPa | |
| Thermal properties | Standard | Value | Measure Units | |
| Coefficient of linear thermal expansion (CLTE) | ||||
| +30°C to +100°C (longitudinal) | ISO 11359 | 5 | × 10ˉ⁶ Kˉ¹ | |
| +30°C a +100°C (transversal) | ISO 11359 | 25 | × 10ˉ⁶ Kˉ¹ | |
| VICAT - Softening point | ||||
| 50N (heating rate 120°C/h) | ISO 306 | 340 | °C | |
| HDT - Heat Deflection Temperature | ||||
| 0.45 MPa | ISO 75 | 340 | °C | |
| 1.81 MPa | ISO 75 | 330 | °C | |
| Thermal conductivity | ||||
| in plane | ASTM E 1461-92 | 0.7 | W/mK | |
| through plane | ASTM E 1461-92 | 0.4 | W/mK | |
| Flammability | Standard | Value | Measure Units | |
| Flammability rating | ||||
| 3 mm thickness | UL 94 | V-0 | ||
| 1.5 mm thickness | UL 94 | V-0 | ||
| GWFI - Glow Wire Flammability Index | ||||
| 2 mm thickness | IEC 60695-2-12 | 960 | °C | |
| GWIT - Glow Wire Ignition Test | ||||
| 2 mm thickness | IEC 60695-2-13 | 825 | °C | |
| Electrical properties | Standard | Value | Measure Units | |
| CTI - Comparative Tracking Index - solution A (without surfactant) | IEC 60112 | 125 | V | |
| Electrical resistivity | ||||
| Surface, dry | IEC 62631 | 1E2 | ohm | |
| Volume | IEC 62631 | 1E6 | ohm.cm | |
| Dielectric strength (short period) | ||||
| 2 mm thickness, 23°C, dry | ASTM D 149 | 3 | kV/mm | |
| Melt Temperature | Standard | Value | Measure Units | |
| Suggested melt temperature | --- | 370 ÷ 400 | °C | |
| Mould Temperature | Standard | Value | Measure Units | |
| Suggested mould temperature | --- | 160 ÷ 210 | °C |