| Physical properties | Standard | Value | Measure Units | 
|---|---|---|---|
| Density | ISO 1183 | 1.66 | g/cm³ | 
| Linear shrinkage at moulding | |||
| Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.20 ÷ 0.35 | % | 
| Transversal (2.0mm/60MPa) | ISO 294-4 | 0.60 ÷ 0.85 | % | 
| Dimensional stability | --- | 68 | |
| Moisture absorption | |||
| Saturation, in air | ISO 62-4 | 0.02 | % | 
| Mechanical properties | Standard | Value | Measure Units | 
| CHARPY impact strength | |||
| Unnotched, at +23°C | ISO 179-1eU | 30 | kJ/m² | 
| Unnotched, at -20°C | ISO 179-1eU | 28 | kJ/m² | 
| Notched, at +23°C | ISO 179-1eA | 10 | kJ/m² | 
| Notched, at -20°C | ISO 179-1eA | 9 | kJ/m² | 
| Tensile elongation | |||
| At break (5 mm/min), 23°C | ISO 527 | 1.5 | % | 
| At break (5 mm/min), 60°C | ISO 527 | 1.6 | % | 
| At break (5 mm/min), 90°C | ISO 527 | 2.3 | % | 
| At break (5 mm/min), 120°C | ISO 527 | 3.2 | % | 
| At break (5 mm/min), 150°C | ISO 527 | 3.4 | % | 
| Tensile strength | |||
| At break (5 mm/min), 23°C | ISO 527 | 175 | MPa | 
| At break (5 mm/min), 60°C | ISO 527 | 165 | MPa | 
| At break (5 mm/min), 90°C | ISO 527 | 145 | MPa | 
| At break (5 mm/min), 120°C | ISO 527 | 95 | MPa | 
| At break (5 mm/min), 150°C | ISO 527 | 75 | MPa | 
| Elastic modulus | |||
| Tensile (1 mm/min), 23°C | ISO 527 | 15000 | MPa | 
| Tensile (1 mm/min), 60°C | ISO 527 | 14500 | MPa | 
| Tensile (1 mm/min), 90°C | ISO 527 | 11000 | MPa | 
| Tensile (1 mm/min), 120°C | ISO 527 | 7500 | MPa | 
| Tensile (1 mm/min), 150°C | ISO 527 | 6100 | MPa | 
| Thermal properties | Standard | Value | Measure Units | 
| Coefficient of linear thermal expansion (CLTE) | |||
| +30°C to +100°C (longitudinal) | ISO 11359 | 15 | × 10ˉ⁶ Kˉ¹ | 
| +30°C a +100°C (transversal) | ISO 11359 | 35 | × 10ˉ⁶ Kˉ¹ | 
| VICAT - Softening point | |||
| 50N (heating rate 120°C/h) | ISO 306 | 260 | °C | 
| HDT - Heat Deflection Temperature | |||
| 0.45 MPa | ISO 75 | 280 | °C | 
| 1.81 MPa | ISO 75 | 270 | °C | 
| Thermal conductivity | |||
| in plane | ASTM E 1461-92 | 0.4 | W/mK | 
| through plane | ASTM E 1461-92 | 0.3 | W/mK | 
| Flammability | Standard | Value | Measure Units | 
| Oxygen Index | ASTM D 2863 | 44 | % | 
| Flammability rating | |||
| 3 mm thickness | UL 94 | V-0 | |
| 1.5 mm thickness | UL 94 | V-0 | |
| 0.75 mm thickness | UL 94 | V-0 | |
| 0.4 mm thickness | UL 94 | V-0 | |
| GWFI - Glow Wire Flammability Index | |||
| 2 mm thickness | IEC 60695-2-12 | 960 | °C | 
| 1 mm thickness | IEC 60695-2-12 | 960 | °C | 
| GWIT - Glow Wire Ignition Test | |||
| 2 mm thickness | IEC 60695-2-13 | 775 | °C | 
| 1 mm thickness | IEC 60695-2-13 | 775 | °C | 
| Electrical properties | Standard | Value | Measure Units | 
| CTI - Comparative Tracking Index - solution A (without surfactant) | IEC 60112 | 125 | V | 
| Electrical resistivity | |||
| Surface, dry | ASTM D 257 / D 4496 | 1E12 | ohm | 
| Dielectric strength (short period) | |||
| 2 mm thickness, 23°C, dry | ASTM D 149 | 18 | kV/mm | 
| Melt Temperature | Standard | Value | Measure Units | 
| Suggested melt temperature | --- | 290 ÷ 330 | °C | 
| Mould Temperature | Standard | Value | Measure Units | 
| Suggested mould temperature | --- | 135 ÷ 150 | °C |