Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATAMID 6 CUVHPX10 G/35

Family: LATAMID 6
Base resin:Polyamide 6 (PA 6)
General information
Compound based on Polyamide 6 (PA 6). Low viscosity. UV stabilised. Heat stabilized. Toughened. Glass fibres. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Toughened
Project challenges
  • - Stain and scratch resistance
  • - UV stability
Additives
  • - Glass fibres
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.41 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.30 ÷ 0.50 %
Transversal (2.0mm/60MPa) ISO 294-4 0.60 ÷ 0.80 %
Dimensional stability --- 68
Moisture absorption
Saturation, in air ISO 62-4 2 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 70 kJ/m²
Unnotched, at -20°C ISO 179-1eU 65 kJ/m²
Notched, at +23°C ISO 179-1eA 10 kJ/m²
Notched, at -20°C ISO 179-1eA 6 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 2.8 %
At break (5 mm/min), 60°C ISO 527 5 %
At break (5 mm/min), 90°C ISO 527 6 %
At break (5 mm/min), 120°C ISO 527 6.4 %
At break (5 mm/min), 150°C ISO 527 6.2 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 145 MPa
At break (5 mm/min), 60°C ISO 527 100 MPa
At break (5 mm/min), 90°C ISO 527 80 MPa
At break (5 mm/min), 120°C ISO 527 70 MPa
At break (5 mm/min), 150°C ISO 527 60 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 9500 MPa
Tensile (1 mm/min), 60°C ISO 527 6500 MPa
Tensile (1 mm/min), 90°C ISO 527 5000 MPa
Tensile (1 mm/min), 120°C ISO 527 4000 MPa
Tensile (1 mm/min), 150°C ISO 527 4000 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 30 × 10⁶ K¹
+30°C a +100°C (transversal) ISO 11359 55 × 10⁶ K¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 215 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 220 °C
1.81 MPa ISO 75 200 °C
Electrical properties Standard Value Measure Units
CTI - Comparative Tracking Index - solution A (without surfactant) IEC 60112 600 V
Electrical resistivity
Surface, dry ASTM D 257 1E12 ohm
Dielectric strength (short period)
2 mm thickness, 23°C, dry ASTM D 149 20 kV/mm
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 235 ÷ 255 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 70 ÷ 100 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 80 ÷ 100°C
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: to be evaluated
Other information
  • Stress - strain curves at different temperatures