Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATAMID 66 H2 G/30

Family: LATAMID 66
Base resin:Polyamide 66 (PA 66)
General information
Compound based on Polyamide 66 (PA 66). Improved thermal stabilisation. Glass fibres. PFAS-free product.
Versions of product mentioned herein are suitable for applications in contact with foodstuffs or for toy manufacturing. Versions of product mentioned herein are suitable for potable water transportation. Nevertheless, manufactured parts have to be verified according to the specific directives.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Additives
  • - Glass fibres
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.36 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.30 ÷ 0.60 %
Transversal (2.0mm/60MPa) ISO 294-4 0.90 ÷ 1.25 %
Dimensional stability --- 55
Moisture absorption
Saturation, in air ISO 62-4 1.75 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 75 kJ/m²
Notched, at +23°C ISO 179-1eA 10 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 3.7 %
At break (5 mm/min), 60°C ISO 527 6.2 %
At break (5 mm/min), 90°C ISO 527 8.3 %
At break (5 mm/min), 120°C ISO 527 9.9 %
At break (5 mm/min), 150°C ISO 527 11 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 175 MPa
At break (5 mm/min), 60°C ISO 527 125 MPa
At break (5 mm/min), 90°C ISO 527 105 MPa
At break (5 mm/min), 120°C ISO 527 95 MPa
At break (5 mm/min), 150°C ISO 527 80 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 8800 MPa
Tensile (1 mm/min), 60°C ISO 527 6200 MPa
Tensile (1 mm/min), 90°C ISO 527 4500 MPa
Tensile (1 mm/min), 120°C ISO 527 4000 MPa
Tensile (1 mm/min), 150°C ISO 527 3800 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 25 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 55 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 255 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 255 °C
1.81 MPa ISO 75 245 °C
Flammability Standard Value Measure Units
Flammability rating
3 mm thickness UL 94 HB
1.5 mm thickness UL 94 HB
0.75 mm thickness UL 94 HB
GWFI - Glow Wire Flammability Index
1.5 mm thickness IEC 60695-2-12 675 °C
GWIT - Glow Wire Ignition Test
1.5 mm thickness IEC 60695-2-13 700 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 1E12 ohm
Dielectric strength (short period)
2 mm thickness, 23°C, dry ASTM D 149 21 kV/mm
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 280 ÷ 300 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 80 ÷ 100 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 80 ÷ 100°C
Injection speed
Injection speed: medium to high. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible
Other information
  • Fatigue curve at 23°C (73°F)
  • Stress - strain at -40°C (-40°F)
  • Stress - strain curves at different temperatures