Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATAMID 66 MDT03-01 G/10 BL:7449F1

Family: LATI MDT
Base resin:Polyamide 66 (PA 66)
General information
Compound based on Polyamide 66 (PA 66). Magnetic detectable filler. Glass fibres. PFAS-free product.
The products mentioned herein are suitable for applications in contact with foodstuffs or for toy manufacturing. Nevertheless, manufactured parts have to be verified according to the specific directives.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Magnetically detectable
Project challenges
  • - Metal detection
Additives
  • - Ceramic fillers
  • - Glass fibres
  • - Metallic powder
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.36 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.60 ÷ 0.90 %
Transversal (2.0mm/60MPa) ISO 294-4 0.95 ÷ 1.35 %
Dimensional stability --- 62
Moisture absorption
Saturation, in air ISO 62-4 2.1 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 35 kJ/m²
Notched, at +23°C ISO 179-1eA 4 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 3.2 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 70 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 4900 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 40 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 75 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 240 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 245 °C
1.81 MPa ISO 75 225 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 280 ÷ 300 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 80 ÷ 100 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 80 ÷ 100°C
Injection speed
Injection speed: medium to high. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible