Physical properties | Standard | Value | Measure Units |
---|---|---|---|
Density | ISO 1183 | 0.9 | g/cm³ |
Linear shrinkage at moulding | |||
Longitudinal (2.0mm/60MPa) | ISO 294-4 | 1.40 ÷ 1.70 | % |
Transversal (2.0mm/60MPa) | ISO 294-4 | 1.45 ÷ 1.75 | % |
Dimensional stability | --- | 74 | |
Moisture absorption | |||
Saturation, in air | ISO 62-4 | 0.07 | % |
Mechanical properties | Standard | Value | Measure Units |
CHARPY impact strength | |||
Notched, at +23°C | ISO 179-1eA | 10 | kJ/m² |
Notched, at -20°C | ISO 179-1eA | 4 | kJ/m² |
Elastic modulus | |||
Tensile (1 mm/min), 23°C | ISO 527 | 1100 | MPa |
Thermal properties | Standard | Value | Measure Units |
Coefficient of linear thermal expansion (CLTE) | |||
+30°C to +100°C (longitudinal) | ISO 11359 | 145 | × 10⁶ K¹ |
+30°C a +100°C (transversal) | ISO 11359 | 145 | × 10⁶ K¹ |
VICAT - Softening point | |||
50N (heating rate 120°C/h) | ISO 306 | 70 | °C |
HDT - Heat Deflection Temperature | |||
0.45 MPa | ISO 75 | 95 | °C |
1.81 MPa | ISO 75 | 55 | °C |
Thermal conductivity | |||
in plane | ASTM E 1461-92 | 0.2 | W/mK |
through plane | ASTM E 1461-92 | 0.2 | W/mK |
Flammability | Standard | Value | Measure Units |
Oxygen Index | ASTM D 2863 | 25 | % |
Flammability rating | |||
1.5 mm thickness | UL 94 | V-2 | |
GWFI - Glow Wire Flammability Index | |||
2 mm thickness | IEC 60695-2-12 | 960 | °C |
1 mm thickness | IEC 60695-2-12 | 960 | °C |
Electrical properties | Standard | Value | Measure Units |
CTI - Comparative Tracking Index - solution A (without surfactant) | IEC 60112 | 600 | V |
Electrical resistivity | |||
Surface, dry | ASTM D 257 | 1E12 | ohm |
Dielectric strength (short period) | |||
2 mm thickness, 23°C, dry | ASTM D 149 | 25 | kV/mm |
Melt Temperature | Standard | Value | Measure Units |
Suggested melt temperature | --- | 190 ÷ 215 | °C |
Mould Temperature | Standard | Value | Measure Units |
Suggested mould temperature | --- | 20 ÷ 40 | °C |