LATIGEA B60

Family: LATIGEA
Base resin:Bio-polymer resin
General information
Product made of Bio-polymer resin from renewable sources. Unfilled. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Additives
  • - Unfilled
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.23 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.35 ÷ 0.50 %
Transversal (2.0mm/60MPa) ISO 294-4 0.50 ÷ 0.70 %
Dimensional stability --- 80
Moisture absorption
Saturation, in air ISO 62-4 0.6 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 50 kJ/m²
Notched, at +23°C ISO 179-1eA 4.5 kJ/m²
Tensile elongation
At yield (5 mm/min), 23°C ISO 527 2.5 %
At break (5 mm/min), 23°C ISO 527 4.5 %
Tensile strength
At yield (5 mm/min), 23°C ISO 527 50 MPa
At break (5 mm/min), 23°C ISO 527 45 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 3000 MPa
Thermal properties Standard Value Measure Units
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 60 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 50 °C
1.81 MPa ISO 75 50 °C
TI - Thermal Index (long term) ASTM E1641/E1877 45 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 1E12 ohm
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 220 ÷ 240 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 15 ÷ 30 °C
Drying conditions (hot air dessiccator)
Predrying needed. At least 4 hours at 60 ÷ 80°C
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible