Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATIGRAY 62-01 CX/75 F3

Family: LATIGRAY
Base resin:Polyamide 6 (PA 6)
General information
Radiopaque compound based on Polyamide 6 (PA 6). Special filler. Potentially suitable for medical contact application. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
Versions of product mentioned herein may support applications in the pharmaceutical, medical or dental sector. Nevertheless, manufactured parts have to be verified according to the specific directives.
Features
  • - Radiopaque / X-ray shielding
Project challenges
  • - Thermal conductivity
  • - X-Ray detectability
Additives
  • - Ceramic fillers
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 2.46 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.60 ÷ 0.90 %
Transversal (2.0mm/60MPa) ISO 294-4 0.60 ÷ 0.90 %
Dimensional stability --- 74
Moisture absorption
Saturation, in air ISO 62-4 0.7 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 24 kJ/m²
Notched, at +23°C ISO 179-1eA 1.3 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 1.1 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 75 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 7900 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 40 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 40 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 180 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 190 °C
1.81 MPa ISO 75 145 °C
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 250 ÷ 270 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 80 ÷ 100 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 80 ÷ 100°C
Injection speed
Injection speed: medium to high. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: not suggested