Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATILUB 66-01M

Family: LATILUB
Base resin:Polyamide 66 (PA 66)
General information
Self-lubricating product based on Polyamide 66 (PA 66). Molybdenum dysulphide. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Self lubricant
  • - Self lubricant, PFAS free
Additives
  • - Molibdenum dysulphide
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.14 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 1.20 ÷ 1.55 %
Transversal (2.0mm/60MPa) ISO 294-4 1.25 ÷ 1.60 %
Dimensional stability --- 70
Moisture absorption
Saturation, in air ISO 62-4 2.3 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 75 kJ/m²
Notched, at +23°C ISO 179-1eA 3.5 kJ/m²
Tensile elongation
At yield (5 mm/min), 23°C ISO 527 2 %
At yield (5 mm/min), 60°C ISO 527 1 %
At break (5 mm/min), 23°C ISO 527 6.8 %
Tensile strength
At yield (5 mm/min), 23°C ISO 527 65 MPa
At yield (5 mm/min), 60°C ISO 527 30 MPa
At break (5 mm/min), 23°C ISO 527 90 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 3300 MPa
Tensile (1 mm/min), 60°C ISO 527 3000 MPa
Tensile (1 mm/min), 90°C ISO 527 1100 MPa
Tensile (1 mm/min), 120°C ISO 527 800 MPa
Tensile (1 mm/min), 150°C ISO 527 700 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 85 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 85 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 225 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 210 °C
1.81 MPa ISO 75 70 °C
Flammability Standard Value Measure Units
Flammability rating
3 mm thickness UL 94 HB
1.5 mm thickness UL 94 HB
0.75 mm thickness UL 94 HB
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Tribological properties Standard Value Measure Units
Wear Factor LATI 3500 10ˉ⁸(mm³m)/N
Friction Coefficient
Static LATI 0.42
Dynamic LATI 0.45
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 270 ÷ 290 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 60 ÷ 90 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 70 ÷ 90°C
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible
Other information
  • Stress - strain curves at different temperatures