Physical properties | Standard | Value | Measure Units |
---|---|---|---|
Density | ISO 1183 | 1.36 | g/cm³ |
Linear shrinkage at moulding | |||
Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.10 ÷ 0.30 | % |
Transversal (2.0mm/60MPa) | ISO 294-4 | 0.50 ÷ 0.80 | % |
Dimensional stability | --- | 62 | |
Moisture absorption | |||
Saturation, in air | ISO 62-4 | 1.55 | % |
Mechanical properties | Standard | Value | Measure Units |
CHARPY impact strength | |||
Unnotched, at +23°C | ISO 179-1eU | 45 | kJ/m² |
Unnotched, at -20°C | ISO 179-1eU | 35 | kJ/m² |
Notched, at +23°C | ISO 179-1eA | 8 | kJ/m² |
Notched, at -20°C | ISO 179-1eA | 6 | kJ/m² |
Tensile elongation | |||
At break (5 mm/min), 23°C | ISO 527 | 1.9 | % |
At break (5 mm/min), 60°C | ISO 527 | 2.5 | % |
At break (5 mm/min), 90°C | ISO 527 | 3.2 | % |
At break (5 mm/min), 120°C | ISO 527 | 3.5 | % |
At break (5 mm/min), 150°C | ISO 527 | 3.8 | % |
Tensile strength | |||
At break (5 mm/min), 23°C | ISO 527 | 220 | MPa |
At break (5 mm/min), 60°C | ISO 527 | 180 | MPa |
At break (5 mm/min), 90°C | ISO 527 | 130 | MPa |
At break (5 mm/min), 120°C | ISO 527 | 110 | MPa |
At break (5 mm/min), 150°C | ISO 527 | 95 | MPa |
Elastic modulus | |||
Tensile (1 mm/min), 23°C | ISO 527 | 22000 | MPa |
Tensile (1 mm/min), 60°C | ISO 527 | 20400 | MPa |
Tensile (1 mm/min), 90°C | ISO 527 | 15000 | MPa |
Tensile (1 mm/min), 120°C | ISO 527 | 11500 | MPa |
Tensile (1 mm/min), 150°C | ISO 527 | 9500 | MPa |
Thermal properties | Standard | Value | Measure Units |
Coefficient of linear thermal expansion (CLTE) | |||
+30°C to +100°C (longitudinal) | ISO 11359 | 15 | × 10ˉ⁶ Kˉ¹ |
+30°C a +100°C (transversal) | ISO 11359 | 45 | × 10ˉ⁶ Kˉ¹ |
VICAT - Softening point | |||
50N (heating rate 120°C/h) | ISO 306 | 250 | °C |
HDT - Heat Deflection Temperature | |||
0.45 MPa | ISO 75 | 260 | °C |
1.81 MPa | ISO 75 | 245 | °C |
Electrical properties | Standard | Value | Measure Units |
Electrical resistivity | |||
Surface, dry | ASTM D 257 / D 4496 | 1E3 | ohm |
Dielectric strength (short period) | |||
2 mm thickness, 23°C, dry | ASTM D 149 | 4 | kV/mm |
Tribological properties | Standard | Value | Measure Units |
Wear Factor | LATI | 80 | 10ˉ⁸(mm³m)/N |
Friction Coefficient | |||
Static | LATI | 0.25 | |
Dynamic | LATI | 0.3 | |
Melt Temperature | Standard | Value | Measure Units |
Suggested melt temperature | --- | 280 ÷ 300 | °C |
Mould Temperature | Standard | Value | Measure Units |
Suggested mould temperature | --- | 80 ÷ 100 | °C |