LATILUB 75/4-02S F1

Family: LATILUB
Base resin:Polybutylene Terephthalate (PBT)
General information
Self-lubricating product based on Polybutylene Terephthalate (PBT). Silicone. PFAS-free product.
Versions of product mentioned herein are suitable for applications in contact with foodstuffs or for toy manufacturing. Nevertheless, manufactured parts have to be verified according to the specific directives.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Self lubricant
  • - Self lubricant, PFAS free
Additives
  • - Silicone
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.29 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 1.70 ÷ 2.00 %
Transversal (2.0mm/60MPa) ISO 294-4 1.70 ÷ 2.00 %
Dimensional stability --- 74
Moisture absorption
Saturation, in air ISO 62-4 0.22 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Notched, at +23°C ISO 179-1eA 6 kJ/m²
Tensile strength
At yield (5 mm/min), 23°C ISO 527 45 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 2400 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 140 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 140 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 170 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 110 °C
1.81 MPa ISO 75 50 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 1E12 ohm
Tribological properties Standard Value Measure Units
Wear Factor LATI 300 10ˉ⁸(mm³m)/N
Friction Coefficient
Static LATI 0.15
Dynamic LATI 0.18
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 230 ÷ 240 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 50 ÷ 70 °C
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 90 ÷ 120°C
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible