Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATIOHM 85-06 PD01 G/15

Family: LATIOHM
Base resin:Polyethersulphone (PESU)
General information
Semiconductive/dissipative product based on Polyethersulphone (PESU). Glass fibres. Intrinsically flame retardant. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - Anti-static or dissipative
  • - Electrically conductive
  • - Intrinsically flame retardant
Project challenges
  • - Electrical conductivity
  • - Electrical dissipation
  • - High temperature usage
  • - Wear and friction
Additives
  • - Glass fibres
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.5 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.10 ÷ 0.25 %
Transversal (2.0mm/60MPa) ISO 294-4 0.25 ÷ 0.45 %
Dimensional stability --- 73
Moisture absorption
Saturation, in air ISO 62-4 0.6 %
At saturation, in water ISO 62-4 1.6 %
Melt Flow Index (MFI) ASTM D 1238 16.00@380°C/2.16kg g/10'
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 25 kJ/m²
Unnotched, at -20°C ISO 179-1eU 25 kJ/m²
Notched, at +23°C ISO 179-1eA 6 kJ/m²
Notched, at -20°C ISO 179-1eA 6 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 1.4 %
At break (5 mm/min), 60°C ISO 527 1.2 %
At break (5 mm/min), 90°C ISO 527 1.2 %
At break (5 mm/min), 120°C ISO 527 1.2 %
At break (5 mm/min), 150°C ISO 527 1 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 145 MPa
At break (5 mm/min), 60°C ISO 527 135 MPa
At break (5 mm/min), 90°C ISO 527 125 MPa
At break (5 mm/min), 120°C ISO 527 105 MPa
At break (5 mm/min), 150°C ISO 527 95 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 13500 MPa
Tensile (1 mm/min), 60°C ISO 527 13500 MPa
Tensile (1 mm/min), 90°C ISO 527 13000 MPa
Tensile (1 mm/min), 120°C ISO 527 12000 MPa
Tensile (1 mm/min), 150°C ISO 527 10500 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 25 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 55 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 215 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 220 °C
1.81 MPa ISO 75 210 °C
Thermal conductivity
in plane ASTM E 1461-92 0.3 W/mK
through plane ASTM E 1461-92 0.3 W/mK
Flammability Standard Value Measure Units
GWFI - Glow Wire Flammability Index
2 mm thickness IEC 60695-2-12 960 °C
GWIT - Glow Wire Ignition Test
2 mm thickness IEC 60695-2-13 825 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 2E2 ohm
1.5 mm thickness UL 94 2E2
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 350 ÷ 380 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 150 ÷ 190 °C
Drying conditions (hot air dessiccator)
Predrying needed. At least 3 hours at 130 ÷ 170°C
Injection speed
Injection speed: medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: possible