| Physical properties | Standard | Value | Measure Units | |
|---|---|---|---|---|
| Density | ISO 1183 | 1.27 | g/cm³ | |
| Linear shrinkage at moulding | ||||
| Longitudinal (2.0mm/60MPa) | ISO 294-4 | 0.20 ÷ 0.35 | % | |
| Transversal (2.0mm/60MPa) | ISO 294-4 | 0.35 ÷ 0.55 | % | |
| Dimensional stability | --- | 64 | ||
| Moisture absorption | ||||
| Saturation, in air | ISO 62-4 | 0.11 | % | |
| Mechanical properties | Standard | Value | Measure Units | |
| CHARPY impact strength | ||||
| Unnotched, at +23°C | ISO 179-1eU | 40 | kJ/m² | |
| Notched, at +23°C | ISO 179-1eA | 12 | kJ/m² | |
| Tensile elongation | ||||
| At break (5 mm/min), 23°C | ISO 527 | 1.8 | % | |
| Tensile strength | ||||
| At break (5 mm/min), 23°C | ISO 527 | 100 | MPa | |
| Elastic modulus | ||||
| Tensile (1 mm/min), 23°C | ISO 527 | 7500 | MPa | |
| Thermal properties | Standard | Value | Measure Units | |
| Coefficient of linear thermal expansion (CLTE) | ||||
| +30°C to +100°C (longitudinal) | ISO 11359 | 25 | × 10ˉ⁶ Kˉ¹ | |
| +30°C a +100°C (transversal) | ISO 11359 | 55 | × 10ˉ⁶ Kˉ¹ | |
| VICAT - Softening point | ||||
| 50N (heating rate 120°C/h) | ISO 306 | 150 | °C | |
| HDT - Heat Deflection Temperature | ||||
| 0.45 MPa | ISO 75 | 145 | °C | |
| 1.81 MPa | ISO 75 | 140 | °C | |
| Flammability | Standard | Value | Measure Units | |
| GWIT - Glow Wire Ignition Test | ||||
| 2 mm thickness | IEC 60695-2-13 | 850 | °C | |
| 1 mm thickness | IEC 60695-2-13 | 850 | °C | |
| Electrical properties | Standard | Value | Measure Units | |
| Electrical resistivity | ||||
| Surface, dry | IEC 62631 | 2E3 | ohm | |
| Volume | IEC 62631 | 3E3 | ohm.cm | |
| Melt Temperature | Standard | Value | Measure Units | |
| Suggested melt temperature | --- | 290 ÷ 300 | °C | |
| Mould Temperature | Standard | Value | Measure Units | |
| Suggested mould temperature | --- | 100 ÷ 120 | °C |