Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATISHIELD 36/SP-08A

Family: LATISHIELD
Base resin:Acrylonitrile-Butadiene-Styrene copolymer (ABS)
General information
EMI shielding product based on Acrylonitrile-Butadiene-Styrene copolymer (ABS). Steel fibres. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - EMI shielding
Project challenges
  • - Electrical dissipation
  • - EMI shielding
  • - Wear and friction
Additives
  • - Steel fibres
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.12 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.65 ÷ 0.85 %
Transversal (2.0mm/60MPa) ISO 294-4 0.70 ÷ 0.90 %
Dimensional stability --- 60
Moisture absorption
Saturation, in air ISO 62-4 0.25 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 20 kJ/m²
Notched, at +23°C ISO 179-1eA 8 kJ/m²
Tensile elongation
At yield (5 mm/min), 23°C ISO 527 2.5 %
At break (5 mm/min), 23°C ISO 527 4 %
Tensile strength
At yield (5 mm/min), 23°C ISO 527 40 MPa
At break (5 mm/min), 23°C ISO 527 40 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 2500 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 80 × 10⁶ K¹
+30°C a +100°C (transversal) ISO 11359 80 × 10⁶ K¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 95 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 95 °C
1.81 MPa ISO 75 80 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 4E1 ohm
1.5 mm thickness UL 94 8E1
Electromagnetic reflection (Bekiscan - CP) --- 95 %
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 190 ÷ 230 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 40 ÷ 60 °C
Drying conditions (hot air dessiccator)
Predrying needed. At least 3 hours at 70 ÷ 80°C
Injection speed
Injection speed: low to medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: not suggested