Customer support: +39-0332 409111
Email: marketing@it.lati.com

LATISHIELD 66-13A G/30

Family: LATISHIELD
Base resin:Polyamide 66 (PA 66)
General information
EMI shielding product based on Polyamide 66 (PA 66). Steel fibres. Glass fibres. PFAS-free product.
The products mentioned herein are not suitable for applications in contact with foodstuffs or for potable water transportation, or for toy manufacturing.
The products mentioned herein are not suitable for applications in the pharmaceutical, medical or dental sector.
Features
  • - EMI shielding
Project challenges
  • - Electrical dissipation
  • - High temperature usage
  • - EMI shielding
  • - Wear and friction
Additives
  • - Steel fibres
  • - Glass fibres
Process types
  • - Injection moulding
Download documents
Technical datasheets
  • IT
  • UK
  • US
  • DE
  • FR
  • ES
  • PT
Technical characteristics
Physical properties Standard Value Measure Units
Density ISO 1183 1.54 g/cm³
Linear shrinkage at moulding
Longitudinal (2.0mm/60MPa) ISO 294-4 0.30 ÷ 0.60 %
Transversal (2.0mm/60MPa) ISO 294-4 0.90 ÷ 1.20 %
Dimensional stability --- 60
Moisture absorption
Saturation, in air ISO 62-4 1.7 %
Mechanical properties Standard Value Measure Units
CHARPY impact strength
Unnotched, at +23°C ISO 179-1eU 50 kJ/m²
Notched, at +23°C ISO 179-1eA 8 kJ/m²
Tensile elongation
At break (5 mm/min), 23°C ISO 527 2 %
Tensile strength
At break (5 mm/min), 23°C ISO 527 120 MPa
Elastic modulus
Tensile (1 mm/min), 23°C ISO 527 9500 MPa
Thermal properties Standard Value Measure Units
Coefficient of linear thermal expansion (CLTE)
+30°C to +100°C (longitudinal) ISO 11359 30 × 10ˉ⁶ Kˉ¹
+30°C a +100°C (transversal) ISO 11359 55 × 10ˉ⁶ Kˉ¹
VICAT - Softening point
50N (heating rate 120°C/h) ISO 306 255 °C
HDT - Heat Deflection Temperature
0.45 MPa ISO 75 260 °C
1.81 MPa ISO 75 245 °C
Electrical properties Standard Value Measure Units
Electrical resistivity
Surface, dry ASTM D 257 / D 4496 8E1 ohm
1.5 mm thickness UL 94 1E2
Electromagnetic reflection (Bekiscan - CP) --- 93 %
Melt Temperature Standard Value Measure Units
Suggested melt temperature --- 280 ÷ 300 °C
Mould Temperature Standard Value Measure Units
Suggested mould temperature --- 80 ÷ 100 °C
Storage
PAY ATTENTION! Material is prone to absorb moisture.
Drying conditions (hot air dessiccator)
Predrying needed. At least 2 hours at 80 ÷ 100°C
Injection speed
Injection speed: low to medium. Setting an injection profile should improve moulding.
Hot runners
Usage of hot runner: not suggested